Necesito apoyo para una falla en AA LG C242CR

Tengo un AA Split LG C242CR que ayer dejo de enfriar. Los filtros están totalmente limpios y no hay ningún codigo de error. ¿Me podrían indicar la causa posible de la falla?

3 respuestas

Respuesta

Pues si tira aire pero no frio muy probable le falte gas rerigerante, se debería comprobar con manómetros.

Respuesta

Most common reasons behind AC not cooling are:
https://www.air-conditioning-ductless.com/

Clogged air filter
If the air conditioner does not cool, the air filter might be clogged. In such case, air cannot flow through properly which greatly reduces the cooling capacity of the air conditioner. Either clean the air filter or replace it as needed.

Dirty coils
If the air conditioner is not cold enough the condenser coils may be dirty and loaded with debris. In an AC, the condenser is like a radiator that dissipates heat (which was removed from the air). The condenser coil must be clean to dissipate heat outside. As the coils get dirtier the air conditioner becomes less efficient, which makes it work harder to cool the room. If the coils are dirty enough, the unit will never be cold enough and will not be able to cool the room.

Insufficient coolant
The coolant circulates through the evaporator coils and cools the air flowing over it and eventually sends cool air into the room. So when the level of this coolant becomes insufficient, the AC fails to cool. At this stage call a PRO for coolant top up and refill.

Faulty compressor
A compressor is the heart of an air conditioning unit which is responsible for cooling your room. If the air conditioner does not cool, the compressor might be defective. The compressor is a motor which compresses the refrigerant or coolant and circulates the refrigerant through the evaporator and condenser coils. If the compressor goes bad the cooling cycle does not start and the AC fails to cool.

Faulty thermostat
A thermostat is a sensor that senses the room temperature and hints the compressor to start or stop the cooling cycle. If the thermostat is defective the air conditioner does not cool or may cool continuously.

Defective parts
The other possible technical reasons behind AC not cooling can be a faulty run capacitor of the compressor, defective control board, bad thermistor, choked capillary, faulty motor etc.

High atmospheric temperature
An AC has an optimum operating temperature (surrounding temperature) at which it can work most effectively. If the temperature shoots up beyond the optimum temperature limit, the efficiency of the air conditioner goes down. Sometime it is so hot outside that a stage is reached where the compressor stops working completely.

Undersized AC
A common mistake people make is that they buy an AC based on their budget and not based on the requirement of the room. A small AC in a huge room will always find hard to cool the room in peak summers. The size of the AC should be according to the size of the room.

Respuesta

Dependiendo si se trata de equipo convencional o invérter puede tratarse de un fallo u otro. En cualquier caso tienes que ver si arranca el compresor, en equipos convencionales suele fallar el condensador de arranque, en caso de invérter podría ser la placa electronica, o simplemente falta de gas. Te aconsejo que acudas a un especialista

Añade tu respuesta